2025-02-20As a key component in the air compressor system, the refrigerated air dryer plays an indispensable role in ensuring dry, clean, and high-quality compressed air. Proper operation and maintenance are critical to stable performance, energy efficiency, and long service life.
1.1 Check that the power supply, voltage, and phase number comply with the nameplate rating (tolerance within ±5%).
1.2 Ensure all piping connections are tightly sealed and secured.
1.3 Confirm the installation location of the compressed air dryer is suitable, stable, and well‑ventilated.
1.4 Verify that the ambient temperature does not exceed the rated value.
For water‑cooled dryers: check whether the cooling water pump is running and the water pressure is sufficient.
2.1 Shut down the air compressor (or close the air inlet and outlet valves of the dryer).
2.2 Power on the refrigerated air dryer; the power indicator will light up. Turn the start switch to ON. The running indicator will illuminate, and the dryer will start operating with refrigerant evaporation.
For R‑22 refrigerant, the low‑pressure gauge should read between 60–70 PSI. After about 5 minutes, the internal cooling system will reach the required cooling temperature.
2.3 Open the ball valve at the top of the automatic drain. The condensed water removed by the dryer will flow into the drain.
The ball valve can remain OPEN at all times.
2.4 Start the air compressor (or open the air inlet and outlet valves). Monitor that the evaporator temperature remains within the normal operating range.
2.5 Maintain an equipment operation log to record inlet and outlet air pressure, refrigerant high/low pressure values, and operating current. Refer to the test report for any abnormalities.
2.6 Shutdown sequence: first close the air supply, then turn the switch to OFF.
3.1 Before operation, release residual air inside the pipeline to ensure safe startup.
3.2 Avoid running the industrial compressed air dryer under no‑load or idle conditions for a long time.
3.3 Do not switch the power button frequently or continuously, so as to prevent overload and tripping. The interval between restart and shutdown must be more than 3 minutes.
4.1 Clean the automatic drain valve regularly to avoid blockage and failure of drainage.
4.2 Clean the radiator / condenser periodically:
-For air‑cooled dryers: use compressed air or a copper brush to clean the condenser to ensure good heat dissipation.
-For water‑cooled dryers: clean the cooling tower and water condenser regularly.
4.3 If the dryer is equipped with a manual drain valve, drain condensed water at least twice a day.
4.4 Always keep the surrounding area of the refrigerated air dryer well‑ventilated.
4.5 Ensure the inlet air temperature of the dryer is always below the rated temperature.